Easter Bank Holiday open 10am until 3pm.  CLOSED Easter Sunday.  

We are open 7 days a week, 9am to 5pm Monday to Friday & 10am until 3pm weekends (Winter Hours and Bank Holidays vary) 

Winter offers - Get 10% off all Evolution Aqua products, use code GET10 at checkout.

Hanna HI-83303K Aquaculture Photometer kit

HI-83303K Aquaculture Photometer kit is an advanced optical system - Unparalleled performance from a benchtop photometer.

Grouped product items
Product Name Quantity
Hanna HI-83303K Aquaculture Photometer kit(TK0056)
£895.00
- +
Hanna HI-93700-01 Ammonia Low Range Reagents 100 tests(TK0059)
£72.95
- +
Hanna HI-93707-01 Nitrite Low Range Reagent 100 tests(TK0060)
£49.95
- +
Hanna HI-93710-01 pH Reagent Phenol Red Method 100 tests(TK0061)
£31.95
- +
Hanna HI-775-26 Reagents For Freshwater Alkalinity Checker HI-775 25 tests(TK0065)
£32.95
- +
Hanna Nitrate Reagents (x100)(TK0062)
£89.95
- +
Hanna HI-93711-01 Total Chlorine Reagent DPD Method 100 tests (TK0067)
£34.95
- +
Hanna HI-93701-01 Free Chlorine Reagent DPD Method 100 Tests(TK0066)
£39.95
- +
Hanna Dissolved Oxygen Reagents (x100)(TK0063)
£79.95
- +
Hanna Phosphate Reagents High Range 0.0 to 30.0 mg/L (x100)(TK0064)
£33.95
- +
Hanna Windows Compatible Software (to handle uploading data via PC connection)(TK0057)
£89.95
- +
Hanna Blue Rugged Case for Bench Meters(TK0071)
£49.95
- +
Hanna USB cable for PC connection(TK0058)
£29.95
- +
Hanna HI-731321 Glass Cuvettes for Checkers & HI-832 HI-833 Series (TK0070)
£36.95
- +
Hanna New Cuvette Caps for New C203 2008 Meter (Pack of 4)(TK0069)
£13.95
- +
Hanna New Cuvette Caps for Old C203 Meter (Pack of 4)(TK0068)
£12.95
- +
In stock

HI-83303K Aquaculture Photometer kit is an advanced optical system - Unparalleled performance from a benchtop photometer.

One meter can be used for both photometric and pH measurements. The meter has 20 different programmed methods measuring 12 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users who would like to develop their own concentration versus absorbance curves. To save valuable benchtop space, the HI-83303 doubles as a professional pH meter with its digital pH/temperature electrode input. Aquaculture parameters include Alkalinity, Calcium, Nitrite, and Phosphate which are critical to maintaining a healthy system. It also contains parameters specific to either a marine or freshwater environment.

The photometer features an innovative optical system that uses LEDs, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source. It ensures accurate and repeatable photometric readings every time.

Made with the aquaculture industry in mind, the HI-83303 is a comprehensive solution to maintaining optimal chemical and environmental conditions, preventing disease and increasing production.

The HI-83303 measures vital parameters such as Alkalinity, Calcium, Nitrite, and Phosphate. Alkalinity plays a part in a dynamic relationship with pH and CO2 concentrations, high alkalinity water lowers fluctuations in pH. The buffering capacity acts to store extra CO2 essential for photosynthesis in the ponds to produce oxygen. Maintaining calcium at certain levels is vital to proper fish growth and development. Excessive nitrite can be toxic to fish. When nitrite interacts with Haemoglobin, the iron becomes oxidised and the blood cell can no longer carry oxygen. Phosphate is essential to plant growth; too much phosphate in an aquaculture system can contribute to algal blooms decreasing dissolved oxygen vital for a successful ecosystem.

HI-83303K Aquaculture Photometer Kit contains

  • HI 83303-02 - meter
  • HI 93700-01 - ammonia tests x 100
  • HI 93732-01 - dissolved oxygen x 100
  • HI 93710-01 - pH tests x 100
  • HI 93728-01 - nitrate tests x 50
  • HI 93707-01 - nitrite tests x 50
  • HI 740222N - blue carrying case
  • Water testing booklet



A digital pH electrode input allows the user to measure pH by a traditional glass electrode.

The HI-83303 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the five wavelengths of light (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.

Two USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.

High Efficiency LED Light Source

An LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue/violet light output.

High Quality Narrow Band Interference Filters

The narrow band interference filter not only ensure greater wavelength accuracy (+/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.

Reference Detector for a Stable Light Source

A beam splitter is used as part of the internal reference system of the HI-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.

Large Cuvette Size

The sample cell of the HI-83303 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.

Focusing Lens for Greater Light Yield

Adding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.

Key features:

  • Advanced optical system with brighter, long-lasting LED light source
  • Backlit 128 x 64 Pixel Graphic Liquid Crystal Display
  • Built-in Reaction Timer for Photometric Measurements
  • Absorbance mode - concentration versus absorbance
  • Units of Measurement plus chemical form displayed
  • Result conversion at the touch of a button
  • Cuvette cover
  • pH and temperature measurement with a single probe
  • Good Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability
  • CAL Check alerts user to potential problems during the calibration process
  • Data Logging - Up to 1000 photometric and pH readings can be stored
  • Logged readings can be quickly and easily transferred to a flash drive or to a PC.
  • Data is exported as a .CSV file for use with spreadsheet programs
  • Battery Status Indicator
  • Error Messages

The Hanna 83303K Aquaculture Photometer kit comes with enough reagents to perform 100 tests for Ammonia, Ph, Dissolved Oxygen and 50 tests for Nitrite and Nitrate, also now comes with free Hanna Carrying Case!

How ehe Hanna 83303K Aquaculture Photometer kit works ? There is no need to calibrate as the test procedure does this for you. Fill the test tube with a clear pond water sample, insert into meter, press the “zero” button (this calibrates the pond water sample to the meter as a reference), add the reagent to the same test tube, Insert back into the meter, press the read timer button, this starts a timer count down, then the Hanna 83303K Aquaculture Photometer kit test meter shows the result on the digital display. All have a 2-year warranty.

We aim to dispatch orders received before midday Monday to Friday on the same day where possible. In most cases our items are available for 1 to 2 day delivery at a competitive price and are trackable via DPD or APC.

Delivery costs for standard items in the UK - £5.95

(Surcharges do apply to remote postcodes)

Heavy items - £9.95

Pipe - £14.95

Palletised items - Some large oversize products, typically items weighing more than 30kg, may require delivery via pallet. Standard Pallet charge is approx. £50.00. To ensure there are no delays with delivery, please include a contact number when placing the order.

Overseas – DHL and UPS, cost based on weight / volume at checkout.